{"id":30962,"date":"2026-11-10T14:18:35","date_gmt":"2026-11-10T06:18:35","guid":{"rendered":"https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/"},"modified":"2026-11-10T14:18:35","modified_gmt":"2026-11-10T06:18:35","slug":"safety-interlock-sto-gate-signal-plc-sequence","status":"publish","type":"post","link":"https:\/\/safetyfencesystems.com\/it\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/","title":{"rendered":"Safety Interlock STO: Tracing the Gate Signal From the Door to the PLC"},"content":{"rendered":"<div class=\"sgf-content-container\">\n<section class=\"hero sgf-pain-box\" id=\"hero\">\n<p class=\"sgf-eyebrow\">SAFETY INTERLOCK STO \/ PLC INTEGRATED SAFETY GATE<\/p>\n<h2>The fence is installed, the door opens, and the machine keeps running<\/h2>\n<p class=\"sgf-summary\">EHS and controls engineers meet this fault from two directions. Either the machine guarding fence is up but opening the gate does not stop the machine, or the line trips so often that production starts bypassing the interlock. Mechanical and electrical teams then blame each other because nobody has written down the chain. Safety interlock STO work starts with a sequence: the actuator key on the gate is withdrawn from the switch body fixed to the post, the safety circuit opens, the drive loses torque and the PLC stops issuing motion commands. Only after the gate is closed and the circuit is deliberately reset can the machine restart. What the guarding supplier contributes is the stable mounting datum and alignment that keep that actuator meeting its switch for years.<\/p>\n<figure class=\"sgf-hero-figure\">\n      <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-safety-interlock-20261110-01.webp\" alt=\"PLC integrated safety gate with a yellow framed mesh machine guard door, black wire mesh and lock hardware mounted on a fixed steel post\"><br \/>\n    <\/figure>\n<p><a class=\"sgf-cta-btn\" href=\"\/it\/contact\/\">Send your gate type and switch model for a mounting carrier drawing<\/a><\/p>\n<\/section>\n<section class=\"specs\" id=\"specs\">\n<h2>The sequence from a mechanical action to a PLC instruction<\/h2>\n<p class=\"sgf-pain-box\">A door that fails to stop the machine is rarely a broken switch. More often the actuator is misaligned, the circuit was designed with an automatic reset, or the mechanical side never gave the switch a fixed, repeatable position. Writing the chain in order assigns each step to an owner.<\/p>\n<div class=\"sgf-table-wrapper\">\n<table class=\"sgf-data-table\">\n<thead>\n<tr>\n<th>Step<\/th>\n<th>What happens, and who owns it<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">1. Mechanical action<\/th>\n<td>The gate leaf opens and the actuator key mounted on it withdraws from the switch body fixed to the post. A framed gate leaf and a door header beam hold both posts parallel so the key tracks the switch instead of drifting out of alignment.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">2. Electrical signal<\/th>\n<td>The safety switch contacts open the safety circuit. A safety lock mounting carrier is prepared for Omron D4NL or Pizzato FS series devices; the switch, its wiring, the safety relay or safety PLC input and the achieved safety rating are specified by the integrator.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">3. Drive and PLC<\/th>\n<td>STO removes torque from the drive and the PLC stops motion commands. STO is not an isolation or a power-off: the drive may remain energised, and vertical axes or gravity loads still need the braking arrangement designed by the machine builder.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">4. Restart inhibit<\/th>\n<td>Closing the gate only re-establishes the circuit. A separate manual reset outside the danger zone, with a clear view of the cell, is required before restart. Without that deliberate action, a door closing on its own could restart the machine with a person still inside.<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/section>\n<section class=\"features sgf-expert-block\" id=\"features\">\n<h2>Where the mechanical side actually makes the difference<\/h2>\n<article class=\"sgf-feature-card\">\n<h3>Alignment is a mechanical part of an electrical function<\/h3>\n<p>Intermittent nuisance stops are usually geometry. A gate leaf that sags pulls the actuator off the switch head; a post that twists moves the switch body; a latch that wears changes the closed position by a few millimetres. Framed mesh panels with a 20x30x1.5 mm tube border, flat full welds and burr-free joints give the gate a rigid leaf, while the header beam keeps the two posts parallel. M8 fixing rings hold the panels and four M10 expansion anchors hold each base plate to the concrete, so the reference position does not move with the floor or the frame.<\/p>\n<figure>\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-safety-interlock-20261110-02.webp\" alt=\"Double swing wire mesh safety gate with lock latch, reinforcing rail and caster supports keeping the actuator aligned with its interlock switch\"><br \/>\n      <\/figure>\n<\/article>\n<article class=\"sgf-feature-card\">\n<h3>A carrier, not a safety control system<\/h3>\n<p>The safety lock mounting carrier is a plate with prepared hole positions for a named third-party switch. It does not contain the safety logic, does not decide the performance level and does not validate the circuit. Robot cell guarding projects also bring light curtains, emergency stops and LOTO into the same safety circuit, and those are designed and signed off by the controls integrator against ISO 14120 and ISO 13849-1 as applicable. Stating that boundary on the drawing is what ends the blame loop: the mechanical contractor proves the door closes to a fixed datum, the electrical contractor proves the circuit behaves as designed.<\/p>\n<figure>\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-safety-interlock-20261110-03.webp\" alt=\"Industrial machine perimeter guarding gate with welded wire mesh, yellow steel frame, latch and a prepared safety interlock mounting position\"><br \/>\n      <\/figure>\n<\/article>\n<article class=\"sgf-feature-card\">\n<h3>Commissioning checks that catch both failure modes<\/h3>\n<p>Record the key-to-switch alignment at closed position, then cycle the gate three to five times and re-measure. Check post verticality, panel flatness, fastener counts and the latch engagement before any electrical fault-finding begins. Then verify with the integrator that opening the gate removes torque, that closing it does not restart the machine, and that only the deliberate reset restores motion. A 1600 J impact figure quoted for the standard configuration applies only to that tested build and must be confirmed per project. This system is not intended for pure pedestrian guidance.<\/p>\n<figure>\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-safety-interlock-20261110-04.webp\" alt=\"Double-leaf industrial safety fence gate with welded mesh panels, locking latch and horizontal reinforcing rail used for interlock alignment checks\"><br \/>\n      <\/figure>\n<\/article>\n<\/section>\n<section class=\"applications\" id=\"applications\">\n<h2>Cells where the door-to-PLC chain should be written down<\/h2>\n<ul>\n<li><strong>Robot cell guarding and palletizer safety guarding:<\/strong> frequent access makes actuator alignment a maintenance item, not a one-off setting.<\/li>\n<li><strong>Protezione di sicurezza per linee di trasporto:<\/strong> gate interlocks and transfer light curtains share one safety circuit with different owners.<\/li>\n<li><strong>CNC machine guards and press shop safety fence:<\/strong> gravity-loaded axes need a braking decision that STO alone does not provide.<\/li>\n<li><strong>Sicurezza nella movimentazione automatizzata dei materiali:<\/strong> restart inhibit protects technicians working inside a partially cleared zone.<\/li>\n<\/ul>\n<p>A PLC integrated safety gate is therefore a joint specification: machine safety fencing supplies the repeatable mechanical datum, and the controls team supplies the circuit that turns it into a stop.<\/p>\n<\/section>\n<section class=\"download\" id=\"download\">\n<h2>What to put in the gate and interlock pack<\/h2>\n<p>Send the gate type and leaf width, door swing, the switch model chosen by the electrical team, the target safety rating, the reset button position and sightline, hazard and LOTO scope, floor and anchor conditions and the number of access points. The returned pack carries the general arrangement with the header beam and gate bay, the lock carrier hole-position drawing, the panel and post BOM, the alignment and gate-cycling checklist and the acceptance records. Electrical schematics, safety circuit validation and PLC logic stay with the integrator.<\/p>\n<\/section>\n<section class=\"bottom_cta\" id=\"bottom-cta\">\n<h2>Give the interlock a position it can keep<\/h2>\n<p>Once the door closes to a fixed, repeatable datum and the circuit has a deliberate reset, the two failure modes separate: misalignment is mechanical, restarts are electrical, and both can be tested at commissioning.<\/p>\n<p><a class=\"sgf-cta-btn\" href=\"\/it\/contact\/\">Request a safety gate and lock carrier drawing<\/a><\/p>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>When a guarded cell keeps running with the gate open, or trips repeatedly, mechanical and electrical teams usually blame each other. Safety interlock STO work writes the chain in order: the actuator key withdraws from the switch body, the safety circuit opens, the drive loses torque and the PLC stops motion commands, with a deliberate manual reset required before restart. A PLC integrated safety gate depends on a repeatable mechanical datum, supplied by a framed gate leaf, a door header beam and a prepared safety lock mounting carrier. The safety circuit, safety rating and validation stay with the controls integrator.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rank_math_focus_keyword":"","rank_math_description":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-30962","post","type-post","status-publish","format-standard","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v19.3 (Yoast SEO v27.6) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Safety Interlock STO | Gate to PLC Sequence<\/title>\n<meta name=\"description\" content=\"Follow the door, actuator key, safety circuit, STO and PLC restart inhibit in order. A framed gate and header beam hold the alignment; the integrator owns the safety circuit design.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/safetyfencesystems.com\/it\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Safety Interlock STO: Tracing the Gate Signal From the Door to the PLC\" \/>\n<meta property=\"og:description\" content=\"Follow the door, actuator key, safety circuit, STO and PLC restart inhibit in order. A framed gate and header beam hold the alignment; the integrator owns the safety circuit design.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/safetyfencesystems.com\/it\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/\" \/>\n<meta property=\"og:site_name\" content=\"Machine Guarding Systems &amp; Industrial Safety Fence Manufacturer\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-10T06:18:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-safety-interlock-20261110-01.webp\" \/>\n<meta name=\"author\" content=\"Hunter\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"Hunter\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/safety-interlock-sto-gate-signal-plc-sequence\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/safety-interlock-sto-gate-signal-plc-sequence\\\/\"},\"author\":{\"name\":\"Hunter\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/#\\\/schema\\\/person\\\/8b566880e8371824aa7bdb09f5ceeabe\"},\"headline\":\"Safety Interlock STO: Tracing the Gate Signal From the Door to the PLC\",\"datePublished\":\"2026-11-10T06:18:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/safety-interlock-sto-gate-signal-plc-sequence\\\/\"},\"wordCount\":1004,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/safety-interlock-sto-gate-signal-plc-sequence\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/safetyfencesystems.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/mdfence-safety-interlock-20261110-01.webp\",\"articleSection\":[\"blog\"],\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/safety-interlock-sto-gate-signal-plc-sequence\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/safety-interlock-sto-gate-signal-plc-sequence\\\/\",\"url\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/safety-interlock-sto-gate-signal-plc-sequence\\\/\",\"name\":\"Safety Interlock STO | Gate to PLC Sequence\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/safety-interlock-sto-gate-signal-plc-sequence\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/safety-interlock-sto-gate-signal-plc-sequence\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/safetyfencesystems.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/mdfence-safety-interlock-20261110-01.webp\",\"datePublished\":\"2026-11-10T06:18:35+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/#\\\/schema\\\/person\\\/8b566880e8371824aa7bdb09f5ceeabe\"},\"description\":\"Follow the door, actuator key, safety circuit, STO and PLC restart inhibit in order. A framed gate and header beam hold the alignment; the integrator owns the safety circuit design.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/safety-interlock-sto-gate-signal-plc-sequence\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/safety-interlock-sto-gate-signal-plc-sequence\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/safety-interlock-sto-gate-signal-plc-sequence\\\/#primaryimage\",\"url\":\"https:\\\/\\\/safetyfencesystems.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/mdfence-safety-interlock-20261110-01.webp\",\"contentUrl\":\"https:\\\/\\\/safetyfencesystems.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/mdfence-safety-interlock-20261110-01.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/safety-interlock-sto-gate-signal-plc-sequence\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/safetyfencesystems.com\\\/it\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Safety Interlock STO: Tracing the Gate Signal From the Door to the PLC\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/#website\",\"url\":\"https:\\\/\\\/safetyfencesystems.com\\\/\",\"name\":\"SGF Security Fence\",\"description\":\"Manufacturer of machine guarding systems and industrial safety fencing for warehouses, factories, and manufacturing plants. OSHA-compliant safety barriers and perimeter fencing solutions.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/safetyfencesystems.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/#\\\/schema\\\/person\\\/8b566880e8371824aa7bdb09f5ceeabe\",\"name\":\"Hunter\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a4eb5b7a0da67283e882df9f7be960d258322174980b4f9a3d7460f236ada96a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a4eb5b7a0da67283e882df9f7be960d258322174980b4f9a3d7460f236ada96a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a4eb5b7a0da67283e882df9f7be960d258322174980b4f9a3d7460f236ada96a?s=96&d=mm&r=g\",\"caption\":\"Hunter\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Safety Interlock STO | Gate to PLC Sequence","description":"Follow the door, actuator key, safety circuit, STO and PLC restart inhibit in order. A framed gate and header beam hold the alignment; the integrator owns the safety circuit design.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/safetyfencesystems.com\/it\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/","og_locale":"it_IT","og_type":"article","og_title":"Safety Interlock STO: Tracing the Gate Signal From the Door to the PLC","og_description":"Follow the door, actuator key, safety circuit, STO and PLC restart inhibit in order. A framed gate and header beam hold the alignment; the integrator owns the safety circuit design.","og_url":"https:\/\/safetyfencesystems.com\/it\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/","og_site_name":"Machine Guarding Systems &amp; Industrial Safety Fence Manufacturer","article_published_time":"2026-11-10T06:18:35+00:00","og_image":[{"url":"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-safety-interlock-20261110-01.webp","type":"","width":"","height":""}],"author":"Hunter","twitter_card":"summary_large_image","twitter_misc":{"Scritto da":"Hunter","Tempo di lettura stimato":"5 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/#article","isPartOf":{"@id":"https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/"},"author":{"name":"Hunter","@id":"https:\/\/safetyfencesystems.com\/#\/schema\/person\/8b566880e8371824aa7bdb09f5ceeabe"},"headline":"Safety Interlock STO: Tracing the Gate Signal From the Door to the PLC","datePublished":"2026-11-10T06:18:35+00:00","mainEntityOfPage":{"@id":"https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/"},"wordCount":1004,"commentCount":0,"image":{"@id":"https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/#primaryimage"},"thumbnailUrl":"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-safety-interlock-20261110-01.webp","articleSection":["blog"],"inLanguage":"it-IT","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/","url":"https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/","name":"Safety Interlock STO | Gate to PLC Sequence","isPartOf":{"@id":"https:\/\/safetyfencesystems.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/#primaryimage"},"image":{"@id":"https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/#primaryimage"},"thumbnailUrl":"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-safety-interlock-20261110-01.webp","datePublished":"2026-11-10T06:18:35+00:00","author":{"@id":"https:\/\/safetyfencesystems.com\/#\/schema\/person\/8b566880e8371824aa7bdb09f5ceeabe"},"description":"Follow the door, actuator key, safety circuit, STO and PLC restart inhibit in order. A framed gate and header beam hold the alignment; the integrator owns the safety circuit design.","breadcrumb":{"@id":"https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/#primaryimage","url":"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-safety-interlock-20261110-01.webp","contentUrl":"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-safety-interlock-20261110-01.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/safetyfencesystems.com\/blog\/safety-interlock-sto-gate-signal-plc-sequence\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/safetyfencesystems.com\/it\/"},{"@type":"ListItem","position":2,"name":"Safety Interlock STO: Tracing the Gate Signal From the Door to the PLC"}]},{"@type":"WebSite","@id":"https:\/\/safetyfencesystems.com\/#website","url":"https:\/\/safetyfencesystems.com\/","name":"Recinzione di sicurezza SGF","description":"Produttore di sistemi di protezione per macchinari e recinzioni di sicurezza industriale per magazzini, fabbriche e impianti di produzione. Barriere di sicurezza conformi alle normative OSHA e soluzioni di recinzione perimetrale.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/safetyfencesystems.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Person","@id":"https:\/\/safetyfencesystems.com\/#\/schema\/person\/8b566880e8371824aa7bdb09f5ceeabe","name":"Cacciatore","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/secure.gravatar.com\/avatar\/a4eb5b7a0da67283e882df9f7be960d258322174980b4f9a3d7460f236ada96a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/a4eb5b7a0da67283e882df9f7be960d258322174980b4f9a3d7460f236ada96a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a4eb5b7a0da67283e882df9f7be960d258322174980b4f9a3d7460f236ada96a?s=96&d=mm&r=g","caption":"Hunter"}}]}},"_links":{"self":[{"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/posts\/30962","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/comments?post=30962"}],"version-history":[{"count":0,"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/posts\/30962\/revisions"}],"wp:attachment":[{"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/media?parent=30962"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/categories?post=30962"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/tags?post=30962"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}