{"id":30988,"date":"2026-11-10T14:59:16","date_gmt":"2026-11-10T06:59:16","guid":{"rendered":"https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/"},"modified":"2026-11-10T14:59:16","modified_gmt":"2026-11-10T06:59:16","slug":"light-curtain-integration-post-detection-vs-physical-gate","status":"publish","type":"post","link":"https:\/\/safetyfencesystems.com\/it\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/","title":{"rendered":"Light Curtain Integration Post: Separating Detection Openings From Maintenance Gates"},"content":{"rendered":"<div class=\"sgf-content-container\">\n<section class=\"hero sgf-pain-box\" id=\"hero\">\n<p class=\"sgf-eyebrow\">LIGHT CURTAIN INTEGRATION POST \/ LIGHT CURTAIN VS PHYSICAL GATE<\/p>\n<h2>A high-frequency infeed opening needs a column, not a cable tie<\/h2>\n<p class=\"sgf-summary\">An integrator replaces a solid door at a busy loading point because opening it slows the cycle, then discovers that the light curtain emitter and receiver have nowhere rigid to mount and the cables hang where a workpiece can catch them. Temporary ties and surface-mounted trunking are the usual result. A dedicated 80&#215;80 mm light curtain integration post solves the mechanical half: the emitter and receiver mount to the guarding structure and the cable runs inside the column, so the detection device and the machine guarding fence become one assembly. The physical gate stays on the maintenance aisle, where occasional access belongs. Deciding light curtain vs physical gate is still a risk assessment question, not a throughput question, and the safety circuit stays with the controls integrator.<\/p>\n<figure class=\"sgf-hero-figure\">\n      <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-light-curtain-post-20261110-01.webp\" alt=\"Long industrial safety fencing run with yellow posts and framed mesh panels alongside an automated high-frequency infeed opening\"><br \/>\n    <\/figure>\n<p><a class=\"sgf-cta-btn\" href=\"\/it\/contact\/\">Send your infeed opening and light curtain model for a column layout<\/a><\/p>\n<\/section>\n<section class=\"specs\" id=\"specs\">\n<h2>What each device is responsible for<\/h2>\n<p class=\"sgf-pain-box\">A light curtain detects presence; a physical gate prevents access by geometry. They are not interchangeable, and mixing them without writing down the boundary is how an opening ends up with neither function properly documented.<\/p>\n<div class=\"sgf-table-wrapper\">\n<table class=\"sgf-data-table\">\n<thead>\n<tr>\n<th>Elemento<\/th>\n<th>Scope on the drawing<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Physical gate<\/th>\n<td>Closes the maintenance route with a framed mesh leaf, heavy-duty hinges, a door header beam and a safety lock mounting carrier. Access is infrequent and deliberate.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Barriera fotoelettrica<\/th>\n<td>Detects entry at the high-frequency material opening. Muting or blanking logic lets product pass without stopping the line; that logic, the device selection and the safety rating belong to the integrator.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">80&#215;80 mm column<\/th>\n<td>Carries the emitter and receiver on a rigid face and routes the cable inside the post. The column is part of the perimeter structure, not a cable management accessory added after commissioning.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">When only a light curtain is acceptable<\/th>\n<td>Only where the risk assessment confirms that no one can remain in the danger zone undetected, that stopping time and approach distance are satisfied, and that local EHS accepts detection instead of a physical barrier. We do not make that determination.<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/section>\n<section class=\"features sgf-expert-block\" id=\"features\">\n<h2>How the column and the fence are drawn as one assembly<\/h2>\n<article class=\"sgf-feature-card\">\n<h3>Hidden cabling needs a service opening, not a hole<\/h3>\n<p>The general arrangement marks the column position, the cable entry and exit points and the inspection opening that lets a technician reach the terminations without dismantling a panel. Framed mesh panels on either side are dimensioned from the column centre line, and any narrow infill is listed in the fence layout BOM with its own part code. Q235 60&#215;60 mm posts and four M10 expansion anchors per base plate keep the adjacent bays aligned, so the emitter and receiver stay on the same optical plane over a long run. Cable type, device model and safety circuit design remain with the electrical team.<\/p>\n<figure>\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-light-curtain-post-20261110-02.webp\" alt=\"Yellow machine safety fence post and base plate with prepared fixing positions for a light curtain integration column and hidden cabling\"><br \/>\n      <\/figure>\n<\/article>\n<article class=\"sgf-feature-card\">\n<h3>Keep the gate where access is rare<\/h3>\n<p>Conveyor line safety guarding normally has both kinds of opening: a transfer point used every cycle and a maintenance door used once a shift. Putting a hinged gate at the transfer point slows production; putting a light curtain at the maintenance door leaves a technician without a lockable, physically closed boundary. The drawing therefore lists gate positions, leaf widths and swing arcs separately from the detection openings, with the safety lock mounting carrier prepared for Omron D4NL or Pizzato FS series switches supplied and wired by the integrator.<\/p>\n<figure>\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-light-curtain-post-20261110-03.webp\" alt=\"Framed mesh maintenance gate with yellow posts and a lock position beside an automated transfer opening in an industrial safety fencing perimeter\"><br \/>\n      <\/figure>\n<\/article>\n<article class=\"sgf-feature-card\">\n<h3>Where coexistence still fails<\/h3>\n<p>A column does not fix an opening that is too short for the required safety distance, a product envelope that forces permanent blanking, or a cell where a person can step past the detection field. Those are ISO 13857 and ISO 14120 questions answered in the risk assessment with stopping time and approach distance recorded. The 1600 J impact figure quoted for the standard guarding configuration applies only to that tested build and does not cover the light curtain device. Aperture, hazard height and reach distance are re-checked on site. This system is not intended for pure pedestrian guidance.<\/p>\n<figure>\n        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-light-curtain-post-20261110-04.webp\" alt=\"Modular machine safety fencing with yellow posts and framed mesh panels forming the boundary around a high-frequency automated loading point\"><br \/>\n      <\/figure>\n<\/article>\n<\/section>\n<section class=\"applications\" id=\"applications\">\n<h2>Openings that benefit from a drawn column<\/h2>\n<ul>\n<li><strong>Conveyor line safety guarding and sortation infeed:<\/strong> product passes continuously while people must stay out.<\/li>\n<li><strong>Palletizer safety guarding and automated material handling safety:<\/strong> a physical door at the outfeed would dominate the cycle time.<\/li>\n<li><strong>Robot cell guarding with a shared load point:<\/strong> the detection field and the lockable maintenance door have different owners.<\/li>\n<li><strong>Warehouse automation safety and AGV handover:<\/strong> exposed cabling at a vehicle route is a repeat failure point.<\/li>\n<\/ul>\n<p>Drawn this way, light curtain vs physical gate becomes two line items on one general arrangement instead of a field modification.<\/p>\n<\/section>\n<section class=\"download\" id=\"download\">\n<h2>The inputs for a combined column and gate drawing<\/h2>\n<p>Send the transfer opening width and height, product envelope and cycle rate, the light curtain model chosen by the integrator, stopping time and approach distance, gate position and swing, hazard heights, floor and anchor conditions and the required service access. The returned pack carries the general arrangement with the column and cable path, the panel and post BOM including narrow infills, the gate and lock carrier schedule and the acceptance checklist. Detection logic, safety rating, electrical schematics and validation stay with the controls integrator and the local risk assessment.<\/p>\n<\/section>\n<section class=\"bottom_cta\" id=\"bottom-cta\">\n<h2>Mount the detection on the structure<\/h2>\n<p>An 80&#215;80 mm column with an internal cable route keeps the emitter aligned and the wiring out of the workpiece path, while the physical gate stays where a person actually needs to enter.<\/p>\n<p><a class=\"sgf-cta-btn\" href=\"\/it\/contact\/\">Request a light curtain integration post layout<\/a><\/p>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Replacing a solid door at a busy infeed slows no cycle if the emitter and receiver have nowhere rigid to mount and the cables hang in the workpiece path. A dedicated 80&#215;80 mm light curtain integration post carries the devices on the guarding structure with the cable routed inside the column. The physical gate stays on the maintenance aisle with its lock carrier. Light curtain vs physical gate is decided by the risk assessment, including stopping time, approach distance and local EHS acceptance; detection logic and the safety circuit stay with the integrator.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rank_math_focus_keyword":"","rank_math_description":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-30988","post","type-post","status-publish","format-standard","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v19.3 (Yoast SEO v27.6) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Light Curtain Integration Post | Detection vs Physical Gate<\/title>\n<meta name=\"description\" content=\"An 80x80 mm column carries the emitter and hides the cabling while a physical gate stays on the maintenance route. Light curtain vs physical gate is a risk assessment decision.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/safetyfencesystems.com\/it\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Light Curtain Integration Post: Separating Detection Openings From Maintenance Gates\" \/>\n<meta property=\"og:description\" content=\"An 80x80 mm column carries the emitter and hides the cabling while a physical gate stays on the maintenance route. Light curtain vs physical gate is a risk assessment decision.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/safetyfencesystems.com\/it\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/\" \/>\n<meta property=\"og:site_name\" content=\"Machine Guarding Systems &amp; Industrial Safety Fence Manufacturer\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-10T06:59:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-light-curtain-post-20261110-01.webp\" \/>\n<meta name=\"author\" content=\"Hunter\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"Hunter\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/light-curtain-integration-post-detection-vs-physical-gate\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/light-curtain-integration-post-detection-vs-physical-gate\\\/\"},\"author\":{\"name\":\"Hunter\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/#\\\/schema\\\/person\\\/8b566880e8371824aa7bdb09f5ceeabe\"},\"headline\":\"Light Curtain Integration Post: Separating Detection Openings From Maintenance Gates\",\"datePublished\":\"2026-11-10T06:59:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/light-curtain-integration-post-detection-vs-physical-gate\\\/\"},\"wordCount\":919,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/light-curtain-integration-post-detection-vs-physical-gate\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/safetyfencesystems.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/mdfence-light-curtain-post-20261110-01.webp\",\"articleSection\":[\"blog\"],\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/light-curtain-integration-post-detection-vs-physical-gate\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/light-curtain-integration-post-detection-vs-physical-gate\\\/\",\"url\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/light-curtain-integration-post-detection-vs-physical-gate\\\/\",\"name\":\"Light Curtain Integration Post | Detection vs Physical Gate\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/light-curtain-integration-post-detection-vs-physical-gate\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/light-curtain-integration-post-detection-vs-physical-gate\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/safetyfencesystems.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/mdfence-light-curtain-post-20261110-01.webp\",\"datePublished\":\"2026-11-10T06:59:16+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/#\\\/schema\\\/person\\\/8b566880e8371824aa7bdb09f5ceeabe\"},\"description\":\"An 80x80 mm column carries the emitter and hides the cabling while a physical gate stays on the maintenance route. Light curtain vs physical gate is a risk assessment decision.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/light-curtain-integration-post-detection-vs-physical-gate\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/light-curtain-integration-post-detection-vs-physical-gate\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/light-curtain-integration-post-detection-vs-physical-gate\\\/#primaryimage\",\"url\":\"https:\\\/\\\/safetyfencesystems.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/mdfence-light-curtain-post-20261110-01.webp\",\"contentUrl\":\"https:\\\/\\\/safetyfencesystems.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/mdfence-light-curtain-post-20261110-01.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/blog\\\/light-curtain-integration-post-detection-vs-physical-gate\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/safetyfencesystems.com\\\/it\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Light Curtain Integration Post: Separating Detection Openings From Maintenance Gates\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/#website\",\"url\":\"https:\\\/\\\/safetyfencesystems.com\\\/\",\"name\":\"SGF Security Fence\",\"description\":\"Manufacturer of machine guarding systems and industrial safety fencing for warehouses, factories, and manufacturing plants. OSHA-compliant safety barriers and perimeter fencing solutions.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/safetyfencesystems.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/safetyfencesystems.com\\\/#\\\/schema\\\/person\\\/8b566880e8371824aa7bdb09f5ceeabe\",\"name\":\"Hunter\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a4eb5b7a0da67283e882df9f7be960d258322174980b4f9a3d7460f236ada96a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a4eb5b7a0da67283e882df9f7be960d258322174980b4f9a3d7460f236ada96a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a4eb5b7a0da67283e882df9f7be960d258322174980b4f9a3d7460f236ada96a?s=96&d=mm&r=g\",\"caption\":\"Hunter\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Light Curtain Integration Post | Detection vs Physical Gate","description":"An 80x80 mm column carries the emitter and hides the cabling while a physical gate stays on the maintenance route. Light curtain vs physical gate is a risk assessment decision.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/safetyfencesystems.com\/it\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/","og_locale":"it_IT","og_type":"article","og_title":"Light Curtain Integration Post: Separating Detection Openings From Maintenance Gates","og_description":"An 80x80 mm column carries the emitter and hides the cabling while a physical gate stays on the maintenance route. Light curtain vs physical gate is a risk assessment decision.","og_url":"https:\/\/safetyfencesystems.com\/it\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/","og_site_name":"Machine Guarding Systems &amp; Industrial Safety Fence Manufacturer","article_published_time":"2026-11-10T06:59:16+00:00","og_image":[{"url":"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-light-curtain-post-20261110-01.webp","type":"","width":"","height":""}],"author":"Hunter","twitter_card":"summary_large_image","twitter_misc":{"Scritto da":"Hunter","Tempo di lettura stimato":"5 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/#article","isPartOf":{"@id":"https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/"},"author":{"name":"Hunter","@id":"https:\/\/safetyfencesystems.com\/#\/schema\/person\/8b566880e8371824aa7bdb09f5ceeabe"},"headline":"Light Curtain Integration Post: Separating Detection Openings From Maintenance Gates","datePublished":"2026-11-10T06:59:16+00:00","mainEntityOfPage":{"@id":"https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/"},"wordCount":919,"commentCount":0,"image":{"@id":"https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/#primaryimage"},"thumbnailUrl":"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-light-curtain-post-20261110-01.webp","articleSection":["blog"],"inLanguage":"it-IT","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/","url":"https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/","name":"Light Curtain Integration Post | Detection vs Physical Gate","isPartOf":{"@id":"https:\/\/safetyfencesystems.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/#primaryimage"},"image":{"@id":"https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/#primaryimage"},"thumbnailUrl":"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-light-curtain-post-20261110-01.webp","datePublished":"2026-11-10T06:59:16+00:00","author":{"@id":"https:\/\/safetyfencesystems.com\/#\/schema\/person\/8b566880e8371824aa7bdb09f5ceeabe"},"description":"An 80x80 mm column carries the emitter and hides the cabling while a physical gate stays on the maintenance route. Light curtain vs physical gate is a risk assessment decision.","breadcrumb":{"@id":"https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/#primaryimage","url":"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-light-curtain-post-20261110-01.webp","contentUrl":"https:\/\/safetyfencesystems.com\/wp-content\/uploads\/2026\/11\/mdfence-light-curtain-post-20261110-01.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/safetyfencesystems.com\/blog\/light-curtain-integration-post-detection-vs-physical-gate\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/safetyfencesystems.com\/it\/"},{"@type":"ListItem","position":2,"name":"Light Curtain Integration Post: Separating Detection Openings From Maintenance Gates"}]},{"@type":"WebSite","@id":"https:\/\/safetyfencesystems.com\/#website","url":"https:\/\/safetyfencesystems.com\/","name":"Recinzione di sicurezza SGF","description":"Produttore di sistemi di protezione per macchinari e recinzioni di sicurezza industriale per magazzini, fabbriche e impianti di produzione. Barriere di sicurezza conformi alle normative OSHA e soluzioni di recinzione perimetrale.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/safetyfencesystems.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Person","@id":"https:\/\/safetyfencesystems.com\/#\/schema\/person\/8b566880e8371824aa7bdb09f5ceeabe","name":"Cacciatore","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/secure.gravatar.com\/avatar\/a4eb5b7a0da67283e882df9f7be960d258322174980b4f9a3d7460f236ada96a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/a4eb5b7a0da67283e882df9f7be960d258322174980b4f9a3d7460f236ada96a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a4eb5b7a0da67283e882df9f7be960d258322174980b4f9a3d7460f236ada96a?s=96&d=mm&r=g","caption":"Hunter"}}]}},"_links":{"self":[{"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/posts\/30988","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/comments?post=30988"}],"version-history":[{"count":0,"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/posts\/30988\/revisions"}],"wp:attachment":[{"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/media?parent=30988"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/categories?post=30988"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/safetyfencesystems.com\/it\/wp-json\/wp\/v2\/tags?post=30988"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}